PD60-2 Partial discharge analysis

By a partial discharge analysis with the cable diagnostics systems PD60-2 or PD60-2/TD by b2hv, the dielectric condition of medium voltage cables can be evaluated.

 

As an expanded device PD60-2/TD comes with an integrated tan delta diagnostics system!

 

PD60-2 partial discharge measurement b2 Suite

PD60-2 partial discharge measurement b2 Suite

 

The cable diagnosis system PD60-2 consists of the following units:

  • HVA60 AC hipot (optional)
  • High voltage filter
  • Coupling capacitor
  • b2 SuiteĀ® software for diagnostics and reporting
  • Set of cables and corona rings

 

The total weight for high voltage filter, coupling capacitor and calibrator is 34 kg. Thus the system is perfectly suitable for mobile use.

 

For partial discharge analysis a sinusoidal 0.1 Hz VLF voltage is employed, adjustable over a range of up to 62 kV peak.

Due to the following features the PD60-2 and PD60-2/TD are the most outstanding systems of their class:

  • Measurement of the intensity of partial discharges versus time
  • Localization of faults by TDR (Time Domain Reflectometry)
  • Display of faults in the partial discharges mapping
  • Phase related depiction
  • b2 SuiteĀ® software for diagnostics and reporting
  • Easy to use and language selection
  • PD60-2/TD offers also integrated tan delta diagnostics


The analysis is documented in the form of a ready-to-use report, containing all relevant results:

  • Calibration Pulse (in accordance with IEC 60270) and end detection
  • Background noise of the measurement arrangement
  • Partial discharges inception voltage (PDIV)
  • Partial discharges level at 1.7 Vo
  • Partial discharges extinction voltage (PDEV)


A SINGLE cable diagnostics system for various applications:

  • Cables: XLPE, PE, PILC
  • Capacitors
  • Switchgear
  • Transformers
  • Rotating machines (IEEE 433)


The PD60-2 enables any test engineer to efficiently perform measurements without extensive training.

 

Other systems of the PD series